Sample Summary
ARSSG Sample ID: 135909
Assessment Report No.: 35256Original Sample Name: R080454
Sample Type: silt
Original X Coordinates: 399133.784896478Original Y Coordinates: 6261559.62312644EPSG SRID: 3156
NAD83 Latitude: 56.4876630744955NAD83 Longitude: -130.638051998924Coordinate Confidence: M
Analyte Abundance Units Detection Limit Method
Ag 0.12 ppm 0.01 Aqua Regia digestion - 3:1 (HC1:HNO3) with ICP analysis
Al 1.73 % 0.01 Aqua Regia digestion - 3:1 (HC1:HNO3) with ICP analysis
As 3.8 ppm 0.1 Aqua Regia digestion - 3:1 (HC1:HNO3) with ICP analysis
Au 0.0226 ppm 0.0001 Aqua Regia digestion - 3:1 (HC1:HNO3) with ICP analysis
Au -0.2 ppm 0.2 Aqua Regia digestion - 3:1 (HC1:HNO3) with ICP analysis
B -10 ppm 10 Aqua Regia digestion - 3:1 (HC1:HNO3) with ICP analysis
Ba 250 ppm 10 Aqua Regia digestion - 3:1 (HC1:HNO3) with ICP analysis
Be 0.34 ppm 0.05 Aqua Regia digestion - 3:1 (HC1:HNO3) with ICP analysis
Bi 0.19 ppm 0.01 Aqua Regia digestion - 3:1 (HC1:HNO3) with ICP analysis
Ca 0.78 % 0.01 Aqua Regia digestion - 3:1 (HC1:HNO3) with ICP analysis
Cd 0.32 ppm 0.01 Aqua Regia digestion - 3:1 (HC1:HNO3) with ICP analysis
Ce 14.35 ppm 0.02 Aqua Regia digestion - 3:1 (HC1:HNO3) with ICP analysis
Co 14.6 ppm 0.1 Aqua Regia digestion - 3:1 (HC1:HNO3) with ICP analysis
Cr 24 ppm 1 Aqua Regia digestion - 3:1 (HC1:HNO3) with ICP analysis
Cs 0.44 ppm 0.05 Aqua Regia digestion - 3:1 (HC1:HNO3) with ICP analysis
Cu 40.0 ppm 0.2 Aqua Regia digestion - 3:1 (HC1:HNO3) with ICP analysis
Fe 3.59 % 0.01 Aqua Regia digestion - 3:1 (HC1:HNO3) with ICP analysis
Ga 5.75 ppm 0.05 Aqua Regia digestion - 3:1 (HC1:HNO3) with ICP analysis
Ge 0.11 ppm 0.05 Aqua Regia digestion - 3:1 (HC1:HNO3) with ICP analysis
Hf 0.12 ppm 0.02 Aqua Regia digestion - 3:1 (HC1:HNO3) with ICP analysis
Hg 0.01 ppm 0.01 Aqua Regia digestion - 3:1 (HC1:HNO3) with ICP analysis
In 0.021 ppm 0.005 Aqua Regia digestion - 3:1 (HC1:HNO3) with ICP analysis
K 0.38 % 0.01 Aqua Regia digestion - 3:1 (HC1:HNO3) with ICP analysis
La 6.7 ppm 0.2 Aqua Regia digestion - 3:1 (HC1:HNO3) with ICP analysis
Li 6.9 ppm 0.1 Aqua Regia digestion - 3:1 (HC1:HNO3) with ICP analysis
Mg 1.41 % 0.01 Aqua Regia digestion - 3:1 (HC1:HNO3) with ICP analysis
Mn 626 ppm 5 Aqua Regia digestion - 3:1 (HC1:HNO3) with ICP analysis
Mo 1.61 ppm 0.05 Aqua Regia digestion - 3:1 (HC1:HNO3) with ICP analysis
Na 0.07 % 0.01 Aqua Regia digestion - 3:1 (HC1:HNO3) with ICP analysis
Nb 0.49 ppm 0.05 Aqua Regia digestion - 3:1 (HC1:HNO3) with ICP analysis
Ni 18.5 ppm 0.2 Aqua Regia digestion - 3:1 (HC1:HNO3) with ICP analysis
P 1180 ppm 10 Aqua Regia digestion - 3:1 (HC1:HNO3) with ICP analysis
Pb 8.0 ppm 0.2 Aqua Regia digestion - 3:1 (HC1:HNO3) with ICP analysis
Rb 12.2 ppm 0.1 Aqua Regia digestion - 3:1 (HC1:HNO3) with ICP analysis
Re -0.001 ppm 0.001 Aqua Regia digestion - 3:1 (HC1:HNO3) with ICP analysis
S 0.36 % 0.01 Aqua Regia digestion - 3:1 (HC1:HNO3) with ICP analysis
Sb 0.32 ppm 0.05 Aqua Regia digestion - 3:1 (HC1:HNO3) with ICP analysis
Sc 4.6 ppm 0.1 Aqua Regia digestion - 3:1 (HC1:HNO3) with ICP analysis
Se 0.9 ppm 0.2 Aqua Regia digestion - 3:1 (HC1:HNO3) with ICP analysis
Sn 0.4 ppm 0.2 Aqua Regia digestion - 3:1 (HC1:HNO3) with ICP analysis
Sr 39.4 ppm 0.2 Aqua Regia digestion - 3:1 (HC1:HNO3) with ICP analysis
Ta 0.01 ppm 0.01 Aqua Regia digestion - 3:1 (HC1:HNO3) with ICP analysis
Te 0.04 ppm 0.01 Aqua Regia digestion - 3:1 (HC1:HNO3) with ICP analysis
Th 1.7 ppm 0.2 Aqua Regia digestion - 3:1 (HC1:HNO3) with ICP analysis
Ti 0.163 % 0.005 Aqua Regia digestion - 3:1 (HC1:HNO3) with ICP analysis
Tl 0.11 ppm 0.02 Aqua Regia digestion - 3:1 (HC1:HNO3) with ICP analysis
U 0.31 ppm 0.05 Aqua Regia digestion - 3:1 (HC1:HNO3) with ICP analysis
V 78 ppm 1 Aqua Regia digestion - 3:1 (HC1:HNO3) with ICP analysis
W 0.22 ppm 0.05 Aqua Regia digestion - 3:1 (HC1:HNO3) with ICP analysis
Wgt 0.82 kg 0.02
Y 9.70 ppm 0.05 Aqua Regia digestion - 3:1 (HC1:HNO3) with ICP analysis
Zn 94 ppm 2 Aqua Regia digestion - 3:1 (HC1:HNO3) with ICP analysis
Zr 4.5 ppm 0.5 Aqua Regia digestion - 3:1 (HC1:HNO3) with ICP analysis