Sample Summary
ARSSG Sample ID: 114424
Assessment Report No.: 37584Original Sample Name: W360484
Sample Type: soilSample Subtype: b horizonSample Depth: 25
Sample Colour: Orange BrownSample Date: 2017-08-18
Original X Coordinates: 464665Original Y Coordinates: 6176926EPSG SRID: 3156
NAD83 Latitude: 55.7367624107541NAD83 Longitude: -129.562742587676Coordinate Confidence: H
Analyte Abundance Units Detection Limit Method
Ag 0.74 ppm 0.01 Aqua Regia digestion - 3:1 (HC1:HNO3) with ICP analysis
Al 3.04 % 0.01 Aqua Regia digestion - 3:1 (HC1:HNO3) with ICP analysis
As 21.4 ppm 0.1 Aqua Regia digestion - 3:1 (HC1:HNO3) with ICP analysis
Au 0.006 ppm 0.001 Aqua Regia digestion - 3:1 (HC1:HNO3) with ICP analysis
B -10 ppm 10 Aqua Regia digestion - 3:1 (HC1:HNO3) with ICP analysis
Ba 60 ppm 10 Aqua Regia digestion - 3:1 (HC1:HNO3) with ICP analysis
Be 0.28 ppm 0.05 Aqua Regia digestion - 3:1 (HC1:HNO3) with ICP analysis
Bi 1.49 ppm 0.01 Aqua Regia digestion - 3:1 (HC1:HNO3) with ICP analysis
Ca 0.02 % 0.01 Aqua Regia digestion - 3:1 (HC1:HNO3) with ICP analysis
Cd 0.15 ppm 0.01 Aqua Regia digestion - 3:1 (HC1:HNO3) with ICP analysis
Ce 28.4 ppm 0.02 Aqua Regia digestion - 3:1 (HC1:HNO3) with ICP analysis
Co 7.8 ppm 0.1 Aqua Regia digestion - 3:1 (HC1:HNO3) with ICP analysis
Cr 31 ppm 1 Aqua Regia digestion - 3:1 (HC1:HNO3) with ICP analysis
Cs 1.65 ppm 0.05 Aqua Regia digestion - 3:1 (HC1:HNO3) with ICP analysis
Cu 21.5 ppm 0.2 Aqua Regia digestion - 3:1 (HC1:HNO3) with ICP analysis
Fe 7.91 % 0.01 Aqua Regia digestion - 3:1 (HC1:HNO3) with ICP analysis
Ga 8.60 ppm 0.05 Aqua Regia digestion - 3:1 (HC1:HNO3) with ICP analysis
Ge -0.05 ppm 0.05 Aqua Regia digestion - 3:1 (HC1:HNO3) with ICP analysis
Hf 0.41 ppm 0.02 Aqua Regia digestion - 3:1 (HC1:HNO3) with ICP analysis
Hg 0.12 ppm 0.01 Aqua Regia digestion - 3:1 (HC1:HNO3) with ICP analysis
In 0.061 ppm 0.005 Aqua Regia digestion - 3:1 (HC1:HNO3) with ICP analysis
K 0.04 % 0.01 Aqua Regia digestion - 3:1 (HC1:HNO3) with ICP analysis
La 18.7 ppm 0.2 Aqua Regia digestion - 3:1 (HC1:HNO3) with ICP analysis
Li 21.2 ppm 0.1 Aqua Regia digestion - 3:1 (HC1:HNO3) with ICP analysis
Mg 0.53 % 0.01 Aqua Regia digestion - 3:1 (HC1:HNO3) with ICP analysis
Mn 788 ppm 5 Aqua Regia digestion - 3:1 (HC1:HNO3) with ICP analysis
Mo 2.40 ppm 0.05 Aqua Regia digestion - 3:1 (HC1:HNO3) with ICP analysis
Na 0.01 % 0.01 Aqua Regia digestion - 3:1 (HC1:HNO3) with ICP analysis
Nb 6.19 ppm 0.05 Aqua Regia digestion - 3:1 (HC1:HNO3) with ICP analysis
Ni 17.8 ppm 0.2 Aqua Regia digestion - 3:1 (HC1:HNO3) with ICP analysis
P 890 ppm 10 Aqua Regia digestion - 3:1 (HC1:HNO3) with ICP analysis
Pb 67.9 ppm 0.2 Aqua Regia digestion - 3:1 (HC1:HNO3) with ICP analysis
Rb 6.7 ppm 0.1 Aqua Regia digestion - 3:1 (HC1:HNO3) with ICP analysis
Re -0.001 ppm 0.001 Aqua Regia digestion - 3:1 (HC1:HNO3) with ICP analysis
S 0.08 % 0.01 Aqua Regia digestion - 3:1 (HC1:HNO3) with ICP analysis
Sb 2.54 ppm 0.05 Aqua Regia digestion - 3:1 (HC1:HNO3) with ICP analysis
Sc 3.6 ppm 0.1 Aqua Regia digestion - 3:1 (HC1:HNO3) with ICP analysis
Se 5.0 ppm 0.2 Aqua Regia digestion - 3:1 (HC1:HNO3) with ICP analysis
Sn 1.0 ppm 0.2 Aqua Regia digestion - 3:1 (HC1:HNO3) with ICP analysis
Sr 2.8 ppm 0.2 Aqua Regia digestion - 3:1 (HC1:HNO3) with ICP analysis
Ta 0.03 ppm 0.01 Aqua Regia digestion - 3:1 (HC1:HNO3) with ICP analysis
Te 0.45 ppm 0.01 Aqua Regia digestion - 3:1 (HC1:HNO3) with ICP analysis
Th 1.3 ppm 0.2 Aqua Regia digestion - 3:1 (HC1:HNO3) with ICP analysis
Ti 0.005 % 0.005 Aqua Regia digestion - 3:1 (HC1:HNO3) with ICP analysis
Tl 0.22 ppm 0.02 Aqua Regia digestion - 3:1 (HC1:HNO3) with ICP analysis
U 0.71 ppm 0.05 Aqua Regia digestion - 3:1 (HC1:HNO3) with ICP analysis
V 64 ppm 1 Aqua Regia digestion - 3:1 (HC1:HNO3) with ICP analysis
W 0.12 ppm 0.05 Aqua Regia digestion - 3:1 (HC1:HNO3) with ICP analysis
Wgt 0.20 kg 0.02
Y 15.95 ppm 0.05 Aqua Regia digestion - 3:1 (HC1:HNO3) with ICP analysis
Zn 92 ppm 2 Aqua Regia digestion - 3:1 (HC1:HNO3) with ICP analysis
Zr 14.1 ppm 0.5 Aqua Regia digestion - 3:1 (HC1:HNO3) with ICP analysis