Sample Summary
ARSSG Sample ID: 114565
Assessment Report No.: 37584Original Sample Name: W363144
Sample Type: soilSample Subtype: b horizonSample Depth: 20
Sample Colour: Light BrownSample Date: 2017-07-10
Original X Coordinates: 462845Original Y Coordinates: 6177797EPSG SRID: 3156
NAD83 Latitude: 55.7444520520128NAD83 Longitude: -129.59184450336Coordinate Confidence: H
Analyte Abundance Units Detection Limit Method
Ag 0.88 ppm 0.01 Aqua Regia digestion - 3:1 (HC1:HNO3) with ICP analysis
Al 2.27 % 0.01 Aqua Regia digestion - 3:1 (HC1:HNO3) with ICP analysis
As 31.6 ppm 0.1 Aqua Regia digestion - 3:1 (HC1:HNO3) with ICP analysis
Au 0.044 ppm 0.001 Aqua Regia digestion - 3:1 (HC1:HNO3) with ICP analysis
B -10 ppm 10 Aqua Regia digestion - 3:1 (HC1:HNO3) with ICP analysis
Ba 100 ppm 10 Aqua Regia digestion - 3:1 (HC1:HNO3) with ICP analysis
Be 0.19 ppm 0.05 Aqua Regia digestion - 3:1 (HC1:HNO3) with ICP analysis
Bi 1.65 ppm 0.01 Aqua Regia digestion - 3:1 (HC1:HNO3) with ICP analysis
Ca 0.02 % 0.01 Aqua Regia digestion - 3:1 (HC1:HNO3) with ICP analysis
Cd 0.05 ppm 0.01 Aqua Regia digestion - 3:1 (HC1:HNO3) with ICP analysis
Ce 21.1 ppm 0.02 Aqua Regia digestion - 3:1 (HC1:HNO3) with ICP analysis
Co 11.2 ppm 0.1 Aqua Regia digestion - 3:1 (HC1:HNO3) with ICP analysis
Cr 19 ppm 1 Aqua Regia digestion - 3:1 (HC1:HNO3) with ICP analysis
Cs 1.99 ppm 0.05 Aqua Regia digestion - 3:1 (HC1:HNO3) with ICP analysis
Cu 43.2 ppm 0.2 Aqua Regia digestion - 3:1 (HC1:HNO3) with ICP analysis
Fe 4.60 % 0.01 Aqua Regia digestion - 3:1 (HC1:HNO3) with ICP analysis
Ga 7.06 ppm 0.05 Aqua Regia digestion - 3:1 (HC1:HNO3) with ICP analysis
Ge -0.05 ppm 0.05 Aqua Regia digestion - 3:1 (HC1:HNO3) with ICP analysis
Hf 0.12 ppm 0.02 Aqua Regia digestion - 3:1 (HC1:HNO3) with ICP analysis
Hg 0.09 ppm 0.01 Aqua Regia digestion - 3:1 (HC1:HNO3) with ICP analysis
In 0.054 ppm 0.005 Aqua Regia digestion - 3:1 (HC1:HNO3) with ICP analysis
K 0.05 % 0.01 Aqua Regia digestion - 3:1 (HC1:HNO3) with ICP analysis
La 11.4 ppm 0.2 Aqua Regia digestion - 3:1 (HC1:HNO3) with ICP analysis
Li 14.5 ppm 0.1 Aqua Regia digestion - 3:1 (HC1:HNO3) with ICP analysis
Mg 0.51 % 0.01 Aqua Regia digestion - 3:1 (HC1:HNO3) with ICP analysis
Mn 1300 ppm 5 Aqua Regia digestion - 3:1 (HC1:HNO3) with ICP analysis
Mo 6.17 ppm 0.05 Aqua Regia digestion - 3:1 (HC1:HNO3) with ICP analysis
Na 0.01 % 0.01 Aqua Regia digestion - 3:1 (HC1:HNO3) with ICP analysis
Nb 0.68 ppm 0.05 Aqua Regia digestion - 3:1 (HC1:HNO3) with ICP analysis
Ni 10.5 ppm 0.2 Aqua Regia digestion - 3:1 (HC1:HNO3) with ICP analysis
P 970 ppm 10 Aqua Regia digestion - 3:1 (HC1:HNO3) with ICP analysis
Pb 19.0 ppm 0.2 Aqua Regia digestion - 3:1 (HC1:HNO3) with ICP analysis
Rb 8.9 ppm 0.1 Aqua Regia digestion - 3:1 (HC1:HNO3) with ICP analysis
Re -0.001 ppm 0.001 Aqua Regia digestion - 3:1 (HC1:HNO3) with ICP analysis
S 0.08 % 0.01 Aqua Regia digestion - 3:1 (HC1:HNO3) with ICP analysis
Sb 2.23 ppm 0.05 Aqua Regia digestion - 3:1 (HC1:HNO3) with ICP analysis
Sc 3.1 ppm 0.1 Aqua Regia digestion - 3:1 (HC1:HNO3) with ICP analysis
Se 2.4 ppm 0.2 Aqua Regia digestion - 3:1 (HC1:HNO3) with ICP analysis
Sn 0.4 ppm 0.2 Aqua Regia digestion - 3:1 (HC1:HNO3) with ICP analysis
Sr 3.0 ppm 0.2 Aqua Regia digestion - 3:1 (HC1:HNO3) with ICP analysis
Ta -0.01 ppm 0.01 Aqua Regia digestion - 3:1 (HC1:HNO3) with ICP analysis
Te 1.25 ppm 0.01 Aqua Regia digestion - 3:1 (HC1:HNO3) with ICP analysis
Th 2.3 ppm 0.2 Aqua Regia digestion - 3:1 (HC1:HNO3) with ICP analysis
Ti 0.005 % 0.005 Aqua Regia digestion - 3:1 (HC1:HNO3) with ICP analysis
Tl 0.22 ppm 0.02 Aqua Regia digestion - 3:1 (HC1:HNO3) with ICP analysis
U 1.01 ppm 0.05 Aqua Regia digestion - 3:1 (HC1:HNO3) with ICP analysis
V 55 ppm 1 Aqua Regia digestion - 3:1 (HC1:HNO3) with ICP analysis
W 0.09 ppm 0.05 Aqua Regia digestion - 3:1 (HC1:HNO3) with ICP analysis
Wgt 0.22 kg 0.02
Y 4.71 ppm 0.05 Aqua Regia digestion - 3:1 (HC1:HNO3) with ICP analysis
Zn 39 ppm 2 Aqua Regia digestion - 3:1 (HC1:HNO3) with ICP analysis
Zr 3.4 ppm 0.5 Aqua Regia digestion - 3:1 (HC1:HNO3) with ICP analysis