Sample Summary
ARSSG Sample ID: 115174
Assessment Report No.: 37584Original Sample Name: W364489
Sample Type: soilSample Subtype: b horizonSample Depth: 15
Sample Colour: Orange BrownSample Date: 2017-08-28
Original X Coordinates: 463652Original Y Coordinates: 6178684EPSG SRID: 3156
NAD83 Latitude: 55.7524828539952NAD83 Longitude: -129.579108529433Coordinate Confidence: H
Analyte Abundance Units Detection Limit Method
Ag 13.55 ppm 0.01 Aqua Regia digestion - 3:1 (HC1:HNO3) with ICP analysis
Al 1.18 % 0.01 Aqua Regia digestion - 3:1 (HC1:HNO3) with ICP analysis
As 625 ppm 0.1 Aqua Regia digestion - 3:1 (HC1:HNO3) with ICP analysis
Au 0.054 ppm 0.001 Aqua Regia digestion - 3:1 (HC1:HNO3) with ICP analysis
B 10 ppm 10 Aqua Regia digestion - 3:1 (HC1:HNO3) with ICP analysis
Ba 750 ppm 10 Aqua Regia digestion - 3:1 (HC1:HNO3) with ICP analysis
Be 1.26 ppm 0.05 Aqua Regia digestion - 3:1 (HC1:HNO3) with ICP analysis
Bi 0.08 ppm 0.01 Aqua Regia digestion - 3:1 (HC1:HNO3) with ICP analysis
Ca 0.21 % 0.01 Aqua Regia digestion - 3:1 (HC1:HNO3) with ICP analysis
Cd 3.46 ppm 0.01 Aqua Regia digestion - 3:1 (HC1:HNO3) with ICP analysis
Ce 48.0 ppm 0.02 Aqua Regia digestion - 3:1 (HC1:HNO3) with ICP analysis
Co 35.8 ppm 0.1 Aqua Regia digestion - 3:1 (HC1:HNO3) with ICP analysis
Cr 6 ppm 1 Aqua Regia digestion - 3:1 (HC1:HNO3) with ICP analysis
Cs 6.80 ppm 0.05 Aqua Regia digestion - 3:1 (HC1:HNO3) with ICP analysis
Cu 68.6 ppm 0.2 Aqua Regia digestion - 3:1 (HC1:HNO3) with ICP analysis
Fe 8.88 % 0.01 Aqua Regia digestion - 3:1 (HC1:HNO3) with ICP analysis
Ga 2.40 ppm 0.05 Aqua Regia digestion - 3:1 (HC1:HNO3) with ICP analysis
Ge 0.14 ppm 0.05 Aqua Regia digestion - 3:1 (HC1:HNO3) with ICP analysis
Hf 0.11 ppm 0.02 Aqua Regia digestion - 3:1 (HC1:HNO3) with ICP analysis
Hg 4.49 ppm 0.01 Aqua Regia digestion - 3:1 (HC1:HNO3) with ICP analysis
In 0.050 ppm 0.005 Aqua Regia digestion - 3:1 (HC1:HNO3) with ICP analysis
K 0.08 % 0.01 Aqua Regia digestion - 3:1 (HC1:HNO3) with ICP analysis
La 23.8 ppm 0.2 Aqua Regia digestion - 3:1 (HC1:HNO3) with ICP analysis
Li 6.2 ppm 0.1 Aqua Regia digestion - 3:1 (HC1:HNO3) with ICP analysis
Mg 0.10 % 0.01 Aqua Regia digestion - 3:1 (HC1:HNO3) with ICP analysis
Mn 6380 ppm 5 Aqua Regia digestion - 3:1 (HC1:HNO3) with ICP analysis
Mo 9.28 ppm 0.05 Aqua Regia digestion - 3:1 (HC1:HNO3) with ICP analysis
Na -0.01 % 0.01 Aqua Regia digestion - 3:1 (HC1:HNO3) with ICP analysis
Nb 0.43 ppm 0.05 Aqua Regia digestion - 3:1 (HC1:HNO3) with ICP analysis
Ni 8.3 ppm 0.2 Aqua Regia digestion - 3:1 (HC1:HNO3) with ICP analysis
P 1680 ppm 10 Aqua Regia digestion - 3:1 (HC1:HNO3) with ICP analysis
Pb 389 ppm 0.2 Aqua Regia digestion - 3:1 (HC1:HNO3) with ICP analysis
Rb 19.3 ppm 0.1 Aqua Regia digestion - 3:1 (HC1:HNO3) with ICP analysis
Re 0.001 ppm 0.001 Aqua Regia digestion - 3:1 (HC1:HNO3) with ICP analysis
S 0.09 % 0.01 Aqua Regia digestion - 3:1 (HC1:HNO3) with ICP analysis
Sb 90.1 ppm 0.05 Aqua Regia digestion - 3:1 (HC1:HNO3) with ICP analysis
Sc 7.0 ppm 0.1 Aqua Regia digestion - 3:1 (HC1:HNO3) with ICP analysis
Se 1.7 ppm 0.2 Aqua Regia digestion - 3:1 (HC1:HNO3) with ICP analysis
Sn 0.3 ppm 0.2 Aqua Regia digestion - 3:1 (HC1:HNO3) with ICP analysis
Sr 16.8 ppm 0.2 Aqua Regia digestion - 3:1 (HC1:HNO3) with ICP analysis
Ta 0.01 ppm 0.01 Aqua Regia digestion - 3:1 (HC1:HNO3) with ICP analysis
Te 0.03 ppm 0.01 Aqua Regia digestion - 3:1 (HC1:HNO3) with ICP analysis
Th 1.2 ppm 0.2 Aqua Regia digestion - 3:1 (HC1:HNO3) with ICP analysis
Ti -0.005 % 0.005 Aqua Regia digestion - 3:1 (HC1:HNO3) with ICP analysis
Tl 7.61 ppm 0.02 Aqua Regia digestion - 3:1 (HC1:HNO3) with ICP analysis
U 1.68 ppm 0.05 Aqua Regia digestion - 3:1 (HC1:HNO3) with ICP analysis
V 34 ppm 1 Aqua Regia digestion - 3:1 (HC1:HNO3) with ICP analysis
W 0.46 ppm 0.05 Aqua Regia digestion - 3:1 (HC1:HNO3) with ICP analysis
Wgt 0.28 kg 0.02
Y 30.5 ppm 0.05 Aqua Regia digestion - 3:1 (HC1:HNO3) with ICP analysis
Zn 275 ppm 2 Aqua Regia digestion - 3:1 (HC1:HNO3) with ICP analysis
Zr 3.2 ppm 0.5 Aqua Regia digestion - 3:1 (HC1:HNO3) with ICP analysis