Sample Summary
ARSSG Sample ID: 115978
Assessment Report No.: 37584Original Sample Name: W607315
Sample Type: soilSample Subtype: b horizonSample Depth: 25
Sample Colour: Orange BrownSample Date: 2017-08-28
Original X Coordinates: 463987Original Y Coordinates: 6177689EPSG SRID: 3156
NAD83 Latitude: 55.7435679467697NAD83 Longitude: -129.573640312206Coordinate Confidence: H
Analyte Abundance Units Detection Limit Method
Ag 0.17 ppm 0.01 Aqua Regia digestion - 3:1 (HC1:HNO3) with ICP analysis
Al 2.69 % 0.01 Aqua Regia digestion - 3:1 (HC1:HNO3) with ICP analysis
As 28.7 ppm 0.1 Aqua Regia digestion - 3:1 (HC1:HNO3) with ICP analysis
Au 0.003 ppm 0.001 Aqua Regia digestion - 3:1 (HC1:HNO3) with ICP analysis
B -10 ppm 10 Aqua Regia digestion - 3:1 (HC1:HNO3) with ICP analysis
Ba 60 ppm 10 Aqua Regia digestion - 3:1 (HC1:HNO3) with ICP analysis
Be 0.23 ppm 0.05 Aqua Regia digestion - 3:1 (HC1:HNO3) with ICP analysis
Bi 0.19 ppm 0.01 Aqua Regia digestion - 3:1 (HC1:HNO3) with ICP analysis
Ca 0.01 % 0.01 Aqua Regia digestion - 3:1 (HC1:HNO3) with ICP analysis
Cd 0.15 ppm 0.01 Aqua Regia digestion - 3:1 (HC1:HNO3) with ICP analysis
Ce 13.20 ppm 0.02 Aqua Regia digestion - 3:1 (HC1:HNO3) with ICP analysis
Co 9.2 ppm 0.1 Aqua Regia digestion - 3:1 (HC1:HNO3) with ICP analysis
Cr 44 ppm 1 Aqua Regia digestion - 3:1 (HC1:HNO3) with ICP analysis
Cs 1.63 ppm 0.05 Aqua Regia digestion - 3:1 (HC1:HNO3) with ICP analysis
Cu 29.0 ppm 0.2 Aqua Regia digestion - 3:1 (HC1:HNO3) with ICP analysis
Fe 5.52 % 0.01 Aqua Regia digestion - 3:1 (HC1:HNO3) with ICP analysis
Ga 11.55 ppm 0.05 Aqua Regia digestion - 3:1 (HC1:HNO3) with ICP analysis
Ge -0.05 ppm 0.05 Aqua Regia digestion - 3:1 (HC1:HNO3) with ICP analysis
Hf 0.21 ppm 0.02 Aqua Regia digestion - 3:1 (HC1:HNO3) with ICP analysis
Hg 0.07 ppm 0.01 Aqua Regia digestion - 3:1 (HC1:HNO3) with ICP analysis
In 0.046 ppm 0.005 Aqua Regia digestion - 3:1 (HC1:HNO3) with ICP analysis
K 0.06 % 0.01 Aqua Regia digestion - 3:1 (HC1:HNO3) with ICP analysis
La 6.9 ppm 0.2 Aqua Regia digestion - 3:1 (HC1:HNO3) with ICP analysis
Li 22.9 ppm 0.1 Aqua Regia digestion - 3:1 (HC1:HNO3) with ICP analysis
Mg 0.67 % 0.01 Aqua Regia digestion - 3:1 (HC1:HNO3) with ICP analysis
Mn 334 ppm 5 Aqua Regia digestion - 3:1 (HC1:HNO3) with ICP analysis
Mo 2.47 ppm 0.05 Aqua Regia digestion - 3:1 (HC1:HNO3) with ICP analysis
Na -0.01 % 0.01 Aqua Regia digestion - 3:1 (HC1:HNO3) with ICP analysis
Nb 5.74 ppm 0.05 Aqua Regia digestion - 3:1 (HC1:HNO3) with ICP analysis
Ni 41.2 ppm 0.2 Aqua Regia digestion - 3:1 (HC1:HNO3) with ICP analysis
P 420 ppm 10 Aqua Regia digestion - 3:1 (HC1:HNO3) with ICP analysis
Pb 10.7 ppm 0.2 Aqua Regia digestion - 3:1 (HC1:HNO3) with ICP analysis
Rb 5.4 ppm 0.1 Aqua Regia digestion - 3:1 (HC1:HNO3) with ICP analysis
Re -0.001 ppm 0.001 Aqua Regia digestion - 3:1 (HC1:HNO3) with ICP analysis
S 0.02 % 0.01 Aqua Regia digestion - 3:1 (HC1:HNO3) with ICP analysis
Sb 3.21 ppm 0.05 Aqua Regia digestion - 3:1 (HC1:HNO3) with ICP analysis
Sc 4.4 ppm 0.1 Aqua Regia digestion - 3:1 (HC1:HNO3) with ICP analysis
Se 1.5 ppm 0.2 Aqua Regia digestion - 3:1 (HC1:HNO3) with ICP analysis
Sn 0.8 ppm 0.2 Aqua Regia digestion - 3:1 (HC1:HNO3) with ICP analysis
Sr 2.8 ppm 0.2 Aqua Regia digestion - 3:1 (HC1:HNO3) with ICP analysis
Ta 0.01 ppm 0.01 Aqua Regia digestion - 3:1 (HC1:HNO3) with ICP analysis
Te 0.07 ppm 0.01 Aqua Regia digestion - 3:1 (HC1:HNO3) with ICP analysis
Th 1.2 ppm 0.2 Aqua Regia digestion - 3:1 (HC1:HNO3) with ICP analysis
Ti 0.010 % 0.005 Aqua Regia digestion - 3:1 (HC1:HNO3) with ICP analysis
Tl 0.20 ppm 0.02 Aqua Regia digestion - 3:1 (HC1:HNO3) with ICP analysis
U 0.52 ppm 0.05 Aqua Regia digestion - 3:1 (HC1:HNO3) with ICP analysis
V 78 ppm 1 Aqua Regia digestion - 3:1 (HC1:HNO3) with ICP analysis
W 0.19 ppm 0.05 Aqua Regia digestion - 3:1 (HC1:HNO3) with ICP analysis
Wgt 0.26 kg 0.02
Y 2.93 ppm 0.05 Aqua Regia digestion - 3:1 (HC1:HNO3) with ICP analysis
Zn 75 ppm 2 Aqua Regia digestion - 3:1 (HC1:HNO3) with ICP analysis
Zr 7.6 ppm 0.5 Aqua Regia digestion - 3:1 (HC1:HNO3) with ICP analysis